Homeowners often ask how often a water heater should be serviced, and the honest answer is, it depends on your water. The mineral load, pH, and microbial content of your supply shape how quickly scale forms, how fast anodes dissolve, and how stressed a burner or heat exchanger becomes. I have pulled heating elements out of four-year-old electric tanks that looked a decade old because of 20+ grains per gallon hardness, and I have opened twelve-year-old tanks on soft city water that https://collinlrpp971.wpsuo.com/tankless-water-heater-installation-gas-vs-electric were still working because they got regular flushing and an anode replacement at the right time. Service frequency is partly a calendar exercise, but mostly a response to the water’s behavior in your specific system.
This guide breaks down maintenance timing for the major water types you’re likely dealing with, plus the signs that tell you to accelerate or delay service. It includes practical details from the field, whether you have a conventional tank, a tankless water heater, or you’re considering water heater installation or water heater replacement. The recommendations are grounded in what actually fails inside these appliances.
What water quality really does inside a heater
Water is never just H2O. Calcium, magnesium, silica, chlorides, dissolved oxygen, hydrogen sulfide, iron, and manganese all matter. In a storage tank, high hardness forms a layer of calcium carbonate that insulates the bottom from the burner or element. That drives up run time and fuel use. It also drums and pops when the burner cycles, which is the classic complaint that brings us to your basement.
In a tankless water heater, the same minerals plate out inside the narrow passages of the heat exchanger. That reduces flow and forces the burner to run hotter to hit your setpoint. A lightly scaled heat exchanger can still make hot water but wastes fuel to do it. A heavily scaled one will start throwing error codes, then shut down. Scale is also abrasive. You see this when you remove a flow sensor with worn vanes or a recirculation bypass valve that no longer seals.
Acidity and chlorides attack metals. Aggressive water eats sacrificial anodes faster, which exposes the tank shell to corrosion. Elevated chloride levels, often in coastal areas or in softened water made from high-chloride sources, can pit stainless steel. That is why some stainless tank manufacturers set chloride limits in their manuals. On the microbial side, sulfur-reducing bacteria create the classic rotten egg smell. They feed on the magnesium anode, which is why swapping to an aluminum zinc anode can tame odor at the cost of slightly faster scale formation.
Service plans should match these tendencies. Hard water demands more frequent flushing and descaling. Aggressive water demands quicker anode checks. Iron and manganese push toward sediment filtration and more frequent drain-downs to keep sludge from burying the drain valve. The right cadence saves fuel, extends life, and reduces emergency calls.
A quick glossary for timing decisions
People use different measures for water quality. A few numbers help anchor the service schedule.
- Hardness: measured in grains per gallon (gpg) or mg/L as CaCO3. Under 4 gpg is soft, 4 to 7 moderately hard, 7 to 15 hard, and above 15 very hard. Field reality: 10 gpg starts to cause noticeable scale problems without mitigation. Total dissolved solids (TDS): a proxy for overall mineral content. Tankless units tend to get finicky above 500 ppm without regular descaling. pH: 6.5 to 8.5 is typical. Below 7 can be corrosive to metals, above 8.5 can promote scale. Chlorides: above about 100 to 150 ppm, stainless components may be vulnerable, depending on metallurgy. Iron/Manganese: even at 0.3 ppm, iron stains and clogs filters. In heaters it becomes sludge.
If you don’t have a lab report, magnet and a kitchen kettle offer clues. White crust on faucets, chalky scale in the kettle, and showerheads that clog every few months point to hard water. Orange staining hints at iron. Rotten egg smell suggests sulfur bacteria.
Service frequency by water type
I group water into five practical categories: soft, normal municipal, moderately hard, very hard, and iron or sulfur rich. If you have a tankless water heater, read the tankless notes in each category because the intervals tighten.
Soft water from a quality softener
Softened water has low calcium and magnesium, which slows scale. It often has higher sodium, and the softener can raise chloride if the source water is brackish. The upside is clean heat transfer, the downside is faster anode depletion and, in certain stainless models, a chloride risk.
Storage tanks do well on soft water with minimal scale, but the anode needs attention. On many houses I service, a new magnesium anode lasts 2 to 4 years on soft water compared to 4 to 7 years on hard untreated water, which sounds counterintuitive until you remember that hard water can form a protective scale on exposed steel.
Recommended schedule for tanks on soft water:
- Annual inspection: check T&P valve, combustion air, venting, burner flame picture or element wiring, and for electric tanks, ohm the elements. Briefly draw from the drain to check for sediment. Listen for rumble. Flush: every 12 to 18 months. You won’t get much out, but it exercises the drain and minimizes valve clogging. Anode check: every 2 years. Replace when the core wire shows or less than 30 percent remains. Consider aluminum zinc if odor is a problem. Burner or element service: clean burner and pilot assembly every 2 to 3 years. Electric elements on soft water often last 7 to 10 years, but test if recovery slows.
Tankless water heater on soft water:
- Descale or check: every 18 to 24 months. Many units will run longer, but the flow sensors and mixing valves appreciate the attention. Filters and screens: clean every 6 to 12 months, especially if you use a recirculation pump. Combustion analysis: annually for gas units. Keep them efficient and safe.
Normal municipal water, low to moderate hardness
Most city water falls between 3 and 8 gpg with pH around neutral. It forms some scale, but not aggressively. Chlorine can be present, which affects rubber seals more than metal in the short term.
Storage tanks on municipal water have predictable maintenance. If I can only see a homeowner once a year, this is the water that makes it easy to keep a tank going past the warranty with low drama.
Recommended schedule for tanks on typical city water:
- Annual inspection and mini-flush: once per year. Draw a gallon or two. If sediment is light, skip a full flush to avoid stirring. If you hear rumble or see flakes, do a full controlled flush. Anode check: every 3 years for magnesium, 4 to 5 for powered anodes. Replace earlier if odor or discoloration starts. Burner service or element check: every 2 years. Replace thermocouples or igniters proactively around year 6 to avoid no-heat calls at inconvenient times. Electric elements usually run 6 to 8 years.
Tankless units on normal municipal water:
- Descale: every 12 to 18 months. The service becomes fast routine once you have isolation valves. Expect 45 to 75 minutes including setup, solution circulation, and rinse. Screen cleaning: every 6 months if the building has old galvanized piping that sheds rust. Otherwise annually is fine. Combustion tune: annually. A small CO rise or drift in manifold pressure catches future igniter or fan issues.
Moderately hard water, no whole-house softener
This is the zone where scale starts to bite your operating cost. A 7 to 12 gpg supply will build a limescale blanket in tanks and will narrow passages in tankless units within a year or two. You can run without a softener, but your service frequency must compensate.
Storage tanks on moderately hard water often pop and rumble during burner cycles. That noise is water flashing to steam under a layer of scale. It is a telltale you should not ignore.
Recommended schedule for tanks on moderately hard water:
- Flush: every 6 to 12 months. Use the pressure relief valve to vent and avoid creating vacuum. If sediment is heavy, plan for a stop-and-start drain with cold water bursts to stir the bottom. Anode check: every 2 years. Magnesium anodes work well here if odor isn’t an issue. Aluminum zinc can reduce smell at a small cost in scale resistance. Burner service: annually. Soot on a gas burner is often a byproduct of longer firing times and poor heat transfer from scale. Clean and verify manifold pressure. Element check (electric): annually. Consider low-watt-density elements to reduce scale baking on the surface.
Tankless units on moderately hard water:
- Descale: every 6 to 12 months. Lean toward 6 months if you keep your setpoint at 130 F or higher, or if you use a recirculation loop. Inlet screen and check valve cleaning: every 6 months. Look for white chips of calcium. If you see a lot of debris, consider a scale reduction cartridge upstream. If a homeowner resists frequent service, talk seriously about a softener or a template-assisted crystallization conditioner. The ongoing cost of descaling plus fuel often equals the cost of treatment in a few years.
Very hard water, 15 gpg or higher
At this level, heaters become scale machines. I have opened tankless heat exchangers after nine months on 20+ gpg water and found them at half flow. For tanks, the bottom can fill with an inch or more of crumbly lime within a year. The burner cycles longer, energy use spikes, and drain valves plug.
If the property does not use a softener, service frequency alone may not keep up. You can maintain aggressively, but discuss water heater replacement timelines honestly. In unfriendly water, an inexpensive tank might last 6 to 8 years with diligence, while the same model on softer water runs 10 to 12.
Recommended schedule for tanks on very hard water:
- Flush: every 3 to 6 months. In practice, I schedule quarterly for the first year, then adjust. If the sediment output drops after a year of steady maintenance, you can stretch to twice a year. Anode check: annually. Swap as needed. Consider a powered anode to reduce odor and corrosion without adding aluminum to the system. Burner or element service: annually minimum. Low-watt-density elements and lower setpoints slow the bake-on. For gas, verify draft and clean the flue passage since scale can push the flame pattern toward yellow.
Tankless units on very hard water:
- Descale: every 3 to 6 months. Shorter interval if you run a recirculation pump, if setpoint is high, or if you see flow errors or short cycling. Consider adding a prefilter and a scale control system. A softener is the most effective. If softening is not possible, use a high-quality anti-scale cartridge and accept you will still descale, just less often. Expect parts wear: flow sensors, EGR-style recirc valves, and mixing valves may need replacement sooner because scale erodes edges and seals.
Iron-rich or sulfur water
Iron and manganese do not scale like calcium, but they create sludge and stain. Sulfur bacteria make hydrogen sulfide gas that reacts at the anode, giving off odor and black residue. The fix is different from hardness control, and the service interval changes.
For tanks on iron or sulfur water, draining is as much about clearing slime as it is about limescale. The smell often leads owners to crank setpoints, which shortens anode life and raises scald risk.
Recommended schedule for tanks on iron or sulfur water:
- Flush: every 6 months to remove sludge. If the drain valve plugs, use a wet vacuum with a hose adapter and remove the cold nipple to vacuum the bottom, or install a full-port drain retrofit. Anode strategy: swap magnesium for aluminum zinc to reduce odor, or install a powered anode. Inspect annually because the chemistry can consume anodes faster than hardness alone would predict. Disinfection: shock chlorinate the tank and lines if odor persists after anode changes. This is a controlled procedure, not a casual bleach dump. In stubborn cases, consider a mixing valve and run higher storage temps to suppress bacterial growth, with caution about scald protection.
Tankless on iron or sulfur water:
- Pre-filtration is essential. A 5 micron sediment filter ahead of the heater extends the life of the flow sensor and prevents fouling. Descale and sanitize annually, more often if odor returns. Hydrogen sulfide can cause nuisance flame sensing issues on some models.
How to read the heater’s own signals
Calendars help, but the water heater sends clear messages when it wants service.
- Popping and rumbling in a gas tank indicate scale blankets on the bottom. Think sooner flushing. Slower recovery on an electric tank hints at scaled elements or a failed lower element. If a shower suddenly runs cooler after a few minutes, suspect the lower element. Cloudy hot water that clears in a glass suggests microbubbles from heating, often worse with scale. Orange particulate hints at rust. A tankless unit that modulates wildly or cycles off at low flows is telling you the heat exchanger is restricted or the flow sensor is sticky. Odor in hot water but not cold points to anode reaction. Address anode choice, not just heater temperature.
When uncertainty remains, pull a sample from the drain. If the first quart is gritty or looks like milk with sand, scale is active. If it is dark with fine sediment, you might have iron or manganese issues. For tankless units, open the screens. White chips or sand-like bits lead you toward hardness control, while black slime suggests bacterial or iron problems upstream.
Tank versus tankless: service philosophy differences
Both types heat water, but they age differently.
Storage tanks are forgiving. They tolerate abuse for a while, then fail in a way that is usually obvious. They like periodic sediment removal, anode attention, and combustion cleanup. Parts are inexpensive. When a tank weld fails, replacement is the path, not repair. If you budget a visit every year, plus a mid-year flush in harder water, you stay ahead.
A tankless water heater needs cleaner water to stay reliable. It is less tolerant of scale in tight passages. The trade-off is efficiency and endless hot water when maintained. Regular descaling is not optional in most areas. Installation matters more: full-size gas lines, proper venting, and isolation valves for service. With those, a tankless can run 15 to 20 years. Without them, 7 to 10 is common and full of nuisance faults. Factor the service kit into any water heater installation.
If you have a recirculation loop, tighten intervals. Recirc keeps water hot in the exchanger or tank, exaggerating scale formation. It also doubles the number of hours seals and check valves see hot chlorinated water. I shorten tankless descale intervals by 25 to 50 percent on recirc systems and check the pump and check valves at every visit.
Where temperature and usage fit into the schedule
Setpoint and draw patterns influence scale speed. Calcium carbonate falls out of solution faster above about 120 F, and much faster as you approach 140 F. Each 10 degree bump can shorten the time to visible scale formation by months in hard water. If you prefer hotter storage temps to increase capacity, plan more frequent service. A mixing valve at the outlet can let you store hotter for Legionella control while delivering safe temperatures, but it does not reduce scale inside the heater.
High-demand homes that empty the tank daily or run multiple showers simultaneously push the heater toward its limits, which magnifies any heat transfer problem. In practice, that means you will notice scale earlier. I encourage heavy-use homes to schedule the first-year check earlier than average. The first year sets the baseline for your water and usage, and you can tune the interval after seeing what the drain produces.
How anode choices change with water
You have three mainstream options: magnesium, aluminum zinc, and powered anodes.
Magnesium anodes protect well and are standard. They can create odor in sulfur water. On moderately hard to soft water, I like magnesium for general use and check at 2 to 3 years.
Aluminum zinc anodes reduce sulfur smell and can help in high iron conditions. They shed aluminum hydroxide that looks like gray jelly when you flush, which alarms some owners but is normal. They can allow slightly more corrosion than magnesium over long intervals, so I check them every 2 years, not longer.
Powered anodes use current to protect the tank without sacrificing metal. They are excellent for odor control and in aggressive waters. Upfront cost is higher, but they remove guesswork and extend tank life in tough conditions. They also remove the variable of water heater replacement due to perforated tanks when maintenance is erratic. On rentals and second homes where service is sporadic, powered anodes pay for themselves in avoided damage.
Practical flushing advice that prevents headaches
Draining a tank sounds simple until the drain valve plugs with scale. If you are doing your own water heater service, a few habits help.
Hook up a short, full-bore hose to the drain. Long garden hoses reduce flow and encourage sediment to settle. Open a hot faucet upstairs to relieve vacuum. If the drain stops, close it, pulse the cold inlet a few seconds, then reopen the drain. The surge stirs sediment toward the outlet. If your drain valve is a narrow plastic style and keeps clogging, have a full-port brass drain installed during the next service.
For tankless descaling, use the manufacturer’s isolation valves, a small pump, and a bucket with 1 to 3 gallons of descaling solution. Food-grade citric acid works for many, though some manufacturers specify proprietary solutions. Run 45 minutes to an hour and reverse flow halfway. Rinse until the discharge pH is near neutral. If you see blue-green tint, you are dissolving copper alloy components, which signals too-strong acid or extended contact. Adjust concentration and time.
When to adjust the schedule after new water heater installation
A new heater gives you a reset. If you just completed water heater installation and do not know your water behavior, schedule a first check at 6 to 12 months for tanks and 6 to 12 months for tankless units. That first visit sets your cadence. I have switched homes from annual to semiannual service after seeing a gallon of scale from a tank at the first flush. I have also stretched intervals after clean drains and calm burners.
If you replaced a failed tank in a hard water home, consider adding treatment during water heater replacement. It is efficient to install a full-port drain valve, an isolation valve kit, or a powered anode when the new unit is accessible and the system is already drained. Spending a little more on the install often saves hours in the next decade.
Cost reality and what to expect from a professional visit
Home service prices vary. As a rough guide, a basic tank inspection and flush may run 100 to 250 dollars, depending on access and region. An anode replacement is often 150 to 350 plus the part. For a tankless water heater repair and descale, expect 150 to 350 for the service, more if parts like flow sensors or ignition assemblies are replaced. These numbers swing with house layout and local rates, but they frame the trade-off between frequent light service and sporadic heavier repairs.
Owners sometimes delay maintenance to save money, then face a stuck drain valve, a perforated tank, or a heat exchanger so scaled that descaling no longer restores flow. I would rather see a homeowner spend small, predictable amounts on maintenance than face a sudden water heater replacement on a holiday weekend. If your budget is tight, prioritize the visit cadence that matches your water type. Even a short annual check catches small issues before they become big ones.
Two short checklists for reference
Annual essentials for storage tanks, regardless of water type:
- Exercise T&P valve and verify no seepage at discharge line. Inspect and clean burner or test electric element circuits, confirm thermostat setpoint. Drain at least a gallon and judge sediment load, then decide whether to fully flush. Check anode status on schedule and watch for odor or discoloration changes. Confirm combustion air, venting integrity, and no backdraft signs.
Annual essentials for tankless units:
- Clean inlet screens and inspect condensate drain if applicable. Descale on schedule for your water hardness, then rinse thoroughly. Run combustion analysis on gas units, verify manifold pressure and CO. Check recirculation pump, check valves, and mixing valve for smooth operation. Review error history in the control board, clear and note any recurring codes.
Putting it all together
If you want a single sentence for the fridge door: schedule tank service annually on soft or municipal water, twice a year on hard water, and quarterly if your water is very hard and untreated. For tankless, descale every 12 to 24 months on soft or municipal water, every 6 to 12 months on moderately hard water, and every 3 to 6 months on very hard water, tightening those intervals if you use recirculation or run hot.
Then listen to your system. Popping is a request to flush. Odor is an anode conversation. Slower flow in a tankless unit is a scale warning. Align water heater service with what your water is doing, not just the calendar. Done consistently, you will spend less on fuel, avoid weekend emergencies, and delay the day you need to talk about water heater replacement.
Animo Plumbing
1050 N Westmoreland Rd, Dallas, TX 75211
(469) 970-5900
Website: https://animoplumbing.com/
Animo Plumbing
Animo PlumbingAnimo Plumbing provides reliable plumbing services in Dallas, TX, available 24/7 for residential and commercial needs.
(469) 970-5900 View on Google MapsBusiness Hours
- Monday: Open 24 hours
- Tuesday: Open 24 hours
- Wednesday: Open 24 hours
- Thursday: Open 24 hours
- Friday: Open 24 hours
- Saturday: Open 24 hours
- Sunday: Open 24 hours